質問 1:View the global IPS configuration, and then answer the question below.
Which of the following statements is true regarding this configuration?
A. FortiGate will spawn IPS engine instances based on the system load.
B. IPS will scan every byte in every session.
C. IPS will use the faster matching algorithm which is only available for units with more than 4 GB memory.
D. New packets will be passed through without inspection if the IPS socket buffer runs out of memory.
正解:B
質問 2:What does the dirty flag mean in a FortiGate session?
A. Traffic has been blocked by the antivirus inspection.
B. The session must be removed from the former primary unit after an HA failover.
C. The next packet must be re-evaluated against the firewall policies.
D. Traffic has been identified as from an application that is not allowed.
正解:C
解説: (Topexam メンバーにのみ表示されます)
質問 3:Which ADVPN configuration must be configured using a script on FortiManager, when using VPN Manager to manage FortiGate VPN tunnels?
A. Enable AD-VPN in IPsec phase 1
B. Configure IP addresses on IPsec virtual interfaces
C. Set protected network to all
D. Disable add-route on hub
正解:A
質問 4:In which two states is a given session categorized as ephemeral? (Choose two.)
A. A UDP session with only one packet received
B. A TCP session waiting for the SYN ACK
C. A TCP session waiting for FIN ACK
D. A UDP session with packets sent and received
正解:A,B
質問 5:Which statement about memory conserve mode is true?
A. A FortiGate starts dropping new sessions when the configured memory use threshold reaches red
B. A FortiGate enters conserve mode when the configured memory use threshold reaches red
C. A FortiGate exits conserve mode when the configured memory use threshold reaches yellow.
D. A FortiGate starts dropping all the new and old sessions when the configured memory use threshold reaches extreme.
正解:B
質問 6:Which two statements about the Security Fabric are true? (Choose two.)
A. All FortiGate devices in the Security Fabric must have bidirectional FortiTelemetry connectivity.
B. FortiGate uses FortiTelemetry protocol to communicate with FortiAnalyzer.
C. Only the root FortiGate collects network information and forwards it to FortiAnalyzer.
D. Branch FortiGate devices must be configured first.
正解:A,B
質問 7:View the IPS exit log, and then answer the question below.
# diagnose test application ipsmonitor 3
ipsengine exit log"
pid = 93 (cfg), duration = 5605322 (s) at Wed Apr 19 09:57:26 2017
code = 11, reason: manual
What is the status of IPS on this FortiGate?
A. IPS daemon experienced a crash.
B. There are communication problems between the IPS engine and the management database.
C. All IPS-related features have been disabled in FortiGate's configuration.
D. IPS engine memory consumption has exceeded the model-specific predefined value.
正解:C
解説: (Topexam メンバーにのみ表示されます)
質問 8:The logs in a FSSO collector agent (CA) are showing the following error:
failed to connect to registry: PIKA1026 (192.168.12.232)
What can be the reason for this error?
A. The remote registry service is not running in the workstation 192.168.12.232.
B. The CA cannot reach the FortiGate with the IP address 192.168.12.232.
C. The CA cannot resolve the name of the workstation.
D. The FortiGate cannot resolve the name of the workstation.
正解:A
解説: (Topexam メンバーにのみ表示されます)
質問 9:Refer to the exhibit, which contains partial output from an IKE real-time debug.
Why did the tunnel not come up?
A. The local gateway has configured less secure encryption and hashing algorithms compared to the remote gateway.
B. The encapsulation method for phase 2 is set to none on local and remote gateways.
C. The Diffie-Hellman group does not match on the local and remote gateways.
D. The proposal ID does not match between local and remote gateways.
正解:A
解説: (Topexam メンバーにのみ表示されます)
弊社のFortinet NSE7_EFW-7.0を利用すれば試験に合格できます
弊社のFortinet NSE7_EFW-7.0は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNSE7_EFW-7.0問題集の質問と答えが間違いないのを保証いたします。
この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のFortinet NSE7_EFW-7.0を利用すれば、君は一回で試験に合格できます。
弊社は無料Fortinet NSE7_EFW-7.0サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NSE7_EFW-7.0サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNSE7_EFW-7.0問題集は自分に適するかどうか判断して購入を決めることができます。
NSE7_EFW-7.0試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
TopExamは君にNSE7_EFW-7.0の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
Fortinet NSE7_EFW-7.0 認定試験の出題範囲:
トピック | 出題範囲 |
---|
トピック 1 | - Troubleshoot different operation modes for a FGCP HA cluster
- Troubleshoot web filtering issues
|
トピック 2 | - Troubleshoot Autodiscovery VPN (ADVPN) to enable on-demand VPN tunnels between sites
- Troubleshoot central management issues
|
トピック 3 | - Diagnose and troubleshoot connectivity problems using built-in tools
- Diagnose and troubleshoot resource problems using built-in tools
|
参照:https://nseti-pdfs.s3.us-west-2.amazonaws.com/desc/Enterprise_Firewall_7.0_Exam_Description.pdf
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNSE7_EFW-7.0問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のFortinet NSE7_EFW-7.0を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNSE7_EFW-7.0問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
一年間の無料更新サービスを提供します
君が弊社のFortinet NSE7_EFW-7.0をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたFortinet NSE7_EFW-7.0をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のFortinet NSE7_EFW-7.0を持っていることを保証します。