質問 1:An enterprise customer has both a NetApp FAS8200 4-node cluster and a third-party storage array in a shared SAN environment. The host servers connect to both storage vendors' arrays in the fabric.
Regarding (he hosts in this scenario, what are- two NetApp best practices when performing this task? (Choose two.)
A. Use separate adapters to connect to each vendors' storage system.
B. Set the default timeout values and storage parameters for the host system.
C. Provide isolation between storage systems using NetApp's multitenancy feature.
D. Always use the same adapter for heterogeneous storage systems.
正解:A,B
質問 2:An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process.
What must the administrator do for this process to work properly?
A. Make the destination LUN larger than the foreign LUN.
B. Zone target ports of source storage with initiator ports of destination storage.
C. Create multiple igroups for the Initiator ports.
D. Create six distinct zones that include specific ports within each zone.
正解:B
質問 3:
A. The zone set must have the same name as the zone.
B. The zone used a wrong zone ID.
C. The WWPN for the NetApp LIF is incorrect.
D. The ONTAP cluster is also attached to the same fabric by way of UTA2. You configure the zoning for the fabric as shown in the exhibit. You discover that the server cannot see its boot LUN.
What is the problem with your zoning configuration?
E. The zone was not activated.
正解:C
質問 4:Exhibit:
An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The hosts are not configured to connect to any other SVM.
Which action should be performed to restore multi-path connectivity to the LUNs in this scenario?
A. Create LIFs on SVM "C" for host connectivity.
B. Move the LUN to a different volume within SVM "C".
C. Move the LUN to SVM "A" to restore connectivity.
D. Move the LUN to SVM "E" to restore connectivity.
正解:A
質問 5:A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme.
In this scenario, what is the problem?
A. A demo license is used.
B. Only one NVMe data LIF can be configured per SVM.
C. The SVM data protocol should be set to FC.
D. The NVMe namespace is not created.
正解:D
質問 6:Which resource would you use to verify whether a specific SAN configuration is supported by NetApp?
A. Active IQ
B. Hardware Universe (HWU)
C. Interoperability Matrix Tool (IMT)
D. SAN Configuration Guide
正解:D
解説: (Topexam メンバーにのみ表示されます)
質問 7:Exhibit:
You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN.
Using MAX Data as shown in the exhibit, which two LUN access protocols are supported with this solution? (Choose two.)
A. FC
B. NVMe
C. iSCSI
D. FCoE
正解:B
質問 8:Exhibit:
Referring to the exhibit. What are two viable scenarios to test LUN multipathing on Host 1?
(Choose two.)
A. Disable one of the FC LIFs on Controller 1.
B. Reboot one of the switches.
C. Disconnect one of the host cables.
D. Reboot Host 1.
正解:B,C
Network Appliance NS0-509 認定試験の出題範囲:
トピック | 出題範囲 |
---|
トピック 1 | - Demonstrate Knowledge Of Clustered Storage System Node Configuration Tasks
|
トピック 2 | - Identify That All Prerequisites For The Installation Of Netapp® System, Hosts, And FCP
- Fcoe Switches Are Verified
|
トピック 3 | - Demonstrate Knowledge Of SVM Configuration Tasks
- Describe How To Configure Host Systems
- Describe How To Configure Switches
|
トピック 4 | - Identify A Detailed Inventory Of SAN Components
- Identify Environmental And Physical Considerations
|
トピック 5 | - Demonstrate Knowledge Of Clustered Storage System Iscsi Configuration Tasks
- Demonstrate Knowledge Of Testing Tasks
|
トピック 6 | - Demonstrate Knowledge Of Clustered Storage System FCP Or Nvme Configuration Tasks
- Demonstrate Knowledge Of Troubleshooting Tasks
|
トピック 7 | - ONTAP SAN Implementation And Configuration
- Describe Switch Configuration Concepts
- Describe Host Configuration Concepts
|
トピック 8 | - Describe The Solution Design And The Hardware Provisioned To Meet Customer’s Requirements And Expectations
|
トピック 9 | - Describe Storage Controller Configuration Concepts
- Describe Storage Space Utilization Or Management Concepts
|
参照:https://www.netapp.com/us/services-support/university/certification/ncie-san.aspx
弊社は無料Network Appliance NS0-509サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NS0-509サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNS0-509問題集は自分に適するかどうか判断して購入を決めることができます。
NS0-509試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
TopExamは君にNS0-509の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
一年間の無料更新サービスを提供します
君が弊社のNetwork Appliance NS0-509をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたNetwork Appliance NS0-509をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のNetwork Appliance NS0-509を持っていることを保証します。
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNS0-509問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のNetwork Appliance NS0-509を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
弊社のNetwork Appliance NS0-509を利用すれば試験に合格できます
弊社のNetwork Appliance NS0-509は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNS0-509問題集の質問と答えが間違いないのを保証いたします。
この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のNetwork Appliance NS0-509を利用すれば、君は一回で試験に合格できます。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNS0-509問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。