質問 1:You are asked to configure the Service Processor on a newly installed node, and must verify the following command:
system-service processor network modify-node local-address-family IPv4-enable true-ip- address 192.168.123.98-netmask 255.255.255.0
Which statement about this command is true?
A. -nodeshould reference the actual node name.
B. IPv6 is required for the SP.
C. The gateway IP address is missing.
D. The Link Local IP Address is missing.
正解:A,C
質問 2:A customer wants to set up storage so that the LUNs have no possibility to go offline.
There are multiple LUNs per volume. There should be extra available space in the volume for snapshot copies.
Which two configuration settings would accomplish task? (Choose two.)
A. Volume guarantee = volumeLUN reservation = enabledFractional reservation
= 0Snapshot autodelete = disabledAutogrow = disabled
B. Volume guarantee = volumeLUN reservation = enabledFractional reservation
= 100%Snapshot autodelete = enabledAutogrow = disabled
C. Volume guarantee = noneLUN reservation = enabledFractional reservation =0Snapshot autodelete = enabledAutogrow = enabled
D. Volume guarantee = volumeLUN reservation = enabledFractional reservation
= 100%Snapshot autodelete = disabledAutogrow = enabled
正解:B,D
質問 3:You have a host that loses connectivity to a LUN after a volume is moved from one node to another node in the cluster. You verified that you do not have a problem with the cluster, a switch, or reporting nodes.
Which two actions will help determine the problem? (Choose two.)
A. Verify that MPIO and ALUA are enabled.
B. Verify that the SnapDrive version is supported for the host and ONTAP version.
C. Verify that the SANtricity Storage Manager version is supported on the host.
D. Verify the HBA timeout settings.
正解:A,D
質問 4:Which two flags would you use to enable NetApp thin provisioning on a LUN? (Choose two.)
A. -spacereserve disabled -spaceallocation disabled
B. -spacereserve enabled -spaceallocation enabled
C. -spacereserve enabled -spaceallocation enabled
D. -spacereserve disabled -spaceallocation enabled
正解:A,D
質問 5:You are planning a migration from a 7-mode system running DATA ONTAP 8.0 to a new
AFF A700 ONTAP 9.1 system. This 7-mode system provides only iSCSI LUNs for a windows server 2012R2 server farm. There is no FC fabric available for this migration.
In this scenario, what would you use for the migration?
A. Unified Host Utility Kit
B. Foreign LUN import (FLI)
C. 7-mode Transition tool (7MTT)
D. OnCommand System Manager
正解:C
質問 6:Which NetApp resource would you use to validate the maximum number of FC hops that are supported by a switch vendor?
A. Switch Install Guide
B. SAN Configuration Guide
C. Installation and Setup Instructions Poster
D. Hardware Universe
正解:B
質問 7:An administrator has an existing FAS3210 running DATA ONTAP 8.2.4 7-mode. They have recently purchased and installed a new AFF A300 ONTAP cluster and need to non- disruptively migrate FC LUNs from the 7-mode system to the new cluster. The administrator has cabled the FC interfaces shown in the exhibit.
In this scenario, which additional cabling will be needed on the AFF A300 to support foreign
LUN import 7-mode?
A. AFF A300 node 1: interface 2a to MDS switch Fabric "B"AFF A300 node 1: interface 2b to MDS switch Fabric "B"AFF A300 node 2: interface 2a to MDS switch Fabric "B"AFF
A300 node 2: interface 2b to MDS switch Fabric "B"
B. AFF A300 node 1: interface 2a to MDS switch Fabric "A"AFF A300 node 1: interface 2b to MDS switch Fabric "A"AFF A300 node 2: interface 2a to MDS switch Fabric "A"AFF
A300 node 2: interface 2b to MDS switch Fabric "A"
C. AFF A300 node 1: interface 2a to MDS switch Fabric "A"AFF A300 node 1: interface 2b to MDS switch Fabric "A"AFF A300 node 2: interface 2a to MDS switch Fabric "B"AFF
A300 node 2: interface 2b to MDS switch Fabric "B"
D. AFF A300 node 1: interface 2a to MDS switch Fabric "A"AFF A300 node 1: interface 2b to MDS switch Fabric "B"AFF A300 node 2: interface 2a to MDS switch Fabric "A"AFF
A300 node 2: interface 2b to MDS switch Fabric "B"
正解:B
質問 8:You want to ensure maximum performance of iSCSI LUNs.
Which statement is correct in this scenario?
A. Configure your network to have Layer 3 switches.
B. Enable flow control on the switch.
C. Use 1GbE instead of 1OGbE.
D. Set the MTU size to 9000.
正解:D
質問 9:The Linux Host Utilities 7.1 configures settings for which three protocols? (Choose three.)
A. SMB
B. NFS
C. iSCSI
D. FCoE
正解:B,C,D
Network Appliance NS0-507 認定試験の出題範囲:
トピック | 出題範囲 |
---|
トピック 1 | - Identify environmental and physical considerations
|
トピック 2 | - ONTAP SAN implementation testing and troubleshooting
|
トピック 3 | - ONTAP SAN implementation and configuration
|
参照:http://www.netapp.com/us/services-support/university/certification/ncie-san/ncie-san-exam.aspx
弊社は無料Network Appliance NS0-507サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NS0-507サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNS0-507問題集は自分に適するかどうか判断して購入を決めることができます。
NS0-507試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNS0-507問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のNetwork Appliance NS0-507を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
TopExamは君にNS0-507の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
弊社のNetwork Appliance NS0-507を利用すれば試験に合格できます
弊社のNetwork Appliance NS0-507は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNS0-507問題集の質問と答えが間違いないのを保証いたします。
この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のNetwork Appliance NS0-507を利用すれば、君は一回で試験に合格できます。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNS0-507問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
一年間の無料更新サービスを提供します
君が弊社のNetwork Appliance NS0-507をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたNetwork Appliance NS0-507をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のNetwork Appliance NS0-507を持っていることを保証します。