質問 1:You need to perform a DR test on a FAS8200 with SAN LUNs using the onboard UTA2 with 16Gb SFP+.
In this scenario, what is the minimum port speed required on the DR Site's FC switches?
A. 8 Gb
B. 16 Gb
C. 2 Gb
D. 4 Gb
正解:B
質問 2:You have a 2-node FAS900 cluster with six FC LIFs per node.
In this scenario, which two methods will limit the total number of paths to eight paths per
LUN? (Choose two.)
A. SLM
B. FC queue depth
C. FC switch zoning
D. Port sets
正解:A,D
質問 3:What are two important considerations when issuing the lun move start command?
(Choose two.)
A. Storage efficiency deduplication metadata is moved with the LUN.
B. LIFs should be available on the destination HA pair.
C. The size of the destination volume must or exceed the size of the LUN.
D. The lun must have a load-sharing mirror to ensure availability during the move.
正解:B,C
質問 4:A customer has 1 TB volume with space guarantee set to volume. Two 100 GBs LUNs are created in the volume with LUN reservation enabled and no snapshot copies exist.
In this scenario, how much space will be shown as used in the volume?
A. 400 GB
B. 200 GB
C. 100 GB
D. 0 GB
正解:B
質問 5:You want to verify back-end SAS cabling on a FAS9000 and SAN host connectivity from windows server 2016, WMware ESX 6.0, and Linux 2.6.
Which two tools would you use to accomplish this task? (Choose two.)
A. Config Advisor
B. nSanity
C. Hardware Universe
D. Interoperability Matrix Tool
正解:A,B
質問 6:You are deploying iSCSI on a newly installed ON TAP cluster. Your network administrator has provided you with 10 Gb network links and physically connected them to your nodes.
According to NetApp best practice, which two network settings should you configure to optimize performance? (Choose two.)
A. Enable jumbo frames.
B. Disable jumbo frames.
C. Disable Ethernet flow control for all ports.
D. Use single initiator, multiple target zoning.
正解:A,C
質問 7:A volume with a single LUN shows 30% deduplication savings. However, the output of df on the cluster does not show the 30% savings back to the volume or aggregate.
What is causing this behavior?
A. LUN space reserve is enabled.
B. LUN space reserve is disabled.
C. Volume space guarantee is set to volume.
D. Volume space guarantee is set to none.
正解:A
質問 8:Which two resources would you use to determine the number of UTA2 ports and the availability of FC support for an AFF A300? (Choose two.)
A. Unified Host Utility Kit
B. Config Advisor
C. Hardware Universe
D. Interoperability Matrix Tool
正解:C,D
質問 9:Which SAN topology is shown in the exhibit?
A. Core-edge
B. Partial mesh
C. Mesh
D. Star
正解:A
Network Appliance NS0-507 認定試験の出題範囲:
トピック | 出題範囲 |
---|
トピック 1 | - Identify environmental and physical considerations
|
トピック 2 | - ONTAP SAN implementation testing and troubleshooting
|
トピック 3 | - ONTAP SAN implementation and configuration
|
参照:http://www.netapp.com/us/services-support/university/certification/ncie-san/ncie-san-exam.aspx
弊社は無料Network Appliance NS0-507サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NS0-507サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNS0-507問題集は自分に適するかどうか判断して購入を決めることができます。
NS0-507試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNS0-507問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のNetwork Appliance NS0-507を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
TopExamは君にNS0-507の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
弊社のNetwork Appliance NS0-507を利用すれば試験に合格できます
弊社のNetwork Appliance NS0-507は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNS0-507問題集の質問と答えが間違いないのを保証いたします。
この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のNetwork Appliance NS0-507を利用すれば、君は一回で試験に合格できます。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNS0-507問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
一年間の無料更新サービスを提供します
君が弊社のNetwork Appliance NS0-507をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたNetwork Appliance NS0-507をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のNetwork Appliance NS0-507を持っていることを保証します。