質問 1:Which three items should be entered to generate a SSL certificate? (Choose three.)
A. Storage Center eth0 IP address(es)
B. Storage Center eth1 IP address(es)
C. DNS Host Name(s)
D. DNS Server IPaddress(es)
E. Storage Center Management IP address
正解:A,C,E
質問 2:A Storage Center system has 6 connections to a FC switch. The Storage Center is in
Virtual Port mode. How many members are in a server zone?
A. 8
B. 4
C. 6
D. 7
正解:A
質問 3:A site has a single Storage Center. An engineer needs to limit access to specific volumes.
These volumes should be accessed by the database administrators only. The engineer must NOT lose any existing performance or data progression capabilities.
Which method should the engineer use to perform this task?
A. create a new Live Volume and give the database administrators access.
B. create replica volumes on a different Storage Center at the remote site
C. create a new disk folder and create the volumes in that folder
D. create a new volume folder and move the desired volumes to the new folder
正解:D
質問 4:Refer to the exhibit.
An engineer needs to correctly configure the fault domain on the Storage Array for the dual-fabric Fibre Channel environment shown. Full connectivity and failover from the storage array configured in legacy port mode for the servers in this environment are required.
Which fault domain configuration meets the requirements?
A. A fault domain that contains P4, P3, P2, and P1; and a fault domain that contains R4, R3, R2, and R1
B. A fault domain that contains P4, R4, P3, and R3; and a fault domain that contains P2, R2, P1, and R1
C. A fault domain that contains P4 and P3, a fault domain that contains R4 and R3, a faultdomain that contains P1 and P2, and a fault domain that contains R1 and R2
D. A fault domain that contains P4 and R4, a fault domain that contains P3 and R3, a fault domain that contains P2 and R2, and a fault domain that contains P1 and R1
正解:B
質問 5:An engineer is performing failover testing on an FC-attached, dual-controller SC8000 system.
The engineer notes that the customer's Windows 2008 R2 servers experience I/O errors.
The RHEL and ESX servers experience no problems.
A11 FC HBA timeouts are configured per Dell best practices.
The Windows servers that are experiencing issues have had no OS-level configuration changes related to SAN storage.
All servers use the same FC fabric.
What is causing the connectivity loss during failover?
A. NPIV is NOT enabled on Storage Center FC local ports.
B. The windows Disk TimeoutValue is NOT set correctly.
C. An incorrect OS type was selected when the Windows server objects were created.
D. The FC cables plugged into the Windows servers have RX and TX reversed.
正解:D
質問 6:An engineer has multiple servers connected to the Storage Center through two iSCSI networks. The engineer uses a software iSCSI initiator on the servers. The Storage Center runs in Virtual Ports mode.
Which IP address is required in the iSCSI initiator for proper connectivity?
A. Management IP address of each controller.
B. Control Port IP address for each domain.
C. Reserve IP address for each domain.
D. Primary IP address for each domain.
正解:B
質問 7:According to the best practices, what are the correct values for the following parameters on a QLogic HBA?
A. Connection options:0 loop onlyLogin retry count:30 attemptsPort down retry count:30 attemptsLink down timeout:30 seconds
B. Connection options:1 - point-to-point onlyLogin retry count:30 attemptsPort down retry count:5attemptsLink down timeout:60 seconds
C. Connection options:1 - point-to-point onlyLogin retry count:60 attemptsPort down retry count:60 attemptsLink down timeout:30 seconds
D. Connection options:0 - Loop onlyLoginretry count:60 attemptsPort down retry count:60 attemptsLink down timeout:30 seconds
正解:B
解説: (Topexam メンバーにのみ表示されます)
質問 8:What are two requirements to enable and use self-encrypting drives (SED)? (Choose two.)
A. A FIPS software license must be applied per Storage Center array.
B. Enterprise Manager must be configured as a KMS.
C. A private key must be uploaded through die USB port by using a pen-drive.
D. An external KMS must be configured.
正解:C,D
一年間の無料更新サービスを提供します
君が弊社のDell DSDSC-200をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたDell DSDSC-200をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のDell DSDSC-200を持っていることを保証します。
TopExamは君にDSDSC-200の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
弊社は無料Dell DSDSC-200サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料DSDSC-200サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのDSDSC-200問題集は自分に適するかどうか判断して購入を決めることができます。
DSDSC-200試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
弊社のDell DSDSC-200を利用すれば試験に合格できます
弊社のDell DSDSC-200は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はDSDSC-200問題集の質問と答えが間違いないのを保証いたします。
この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のDell DSDSC-200を利用すれば、君は一回で試験に合格できます。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のDSDSC-200問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
弊社は失敗したら全額で返金することを承諾します
我々は弊社のDSDSC-200問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のDell DSDSC-200を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
Dell DSDSC-200 認定試験の出題範囲:
トピック | 出題範囲 |
---|
トピック 1 | - Deployment and Configuration: Installation, configuration, and deployment processes of SC Series storage arrays.
|
トピック 2 | - Storage Architecture & Features: Understanding the architecture of Dell SC Series storage, including the hardware and software components.
|
トピック 3 | - Data Protection & Backup Solutions: Implementing data protection mechanisms such as replication, snapshots, and backups.
|
トピック 4 | - Management Tools: Using Dell-specific management tools and the overall storage management interface to configure and maintain storage systems.
|
トピック 5 | - Performance and Optimization: How to optimize and monitor storage performance effectively, including tuning and troubleshooting strategies.
|
トピック 6 | - Scalability and Virtualization: Managing storage scalability and integrating with virtualization technologies (e.g., VMware, Hyper-V).
|
参照:https://partnerdirect.dell.com/sites/channel/en-em/documents/dell-training-and-certification-learning-path-083116a-server-launch.pdf